Overview
When certain components are reset or replaced, a FUYL Locker may require an Address Locks procedure be performed. This process re-familiarises the control door with the location, firmware version and order of each of the locks.
Prerequisites
- A FUYL 5 or 15 Locker (excluding MK1). Help with identifying a FUYL Locker
- An administrator key
- An administrator PIN (default is 31082018 if this is a newly reset unit)
Procedure
FUYL Pro (MK3)
- Power down the FUYL Locker
- Open the side door with the administrator key
- Ensure the physical connections to each bay are secure
- Power on the FUYL Locker (all LEDs should show some activity)
- Access the administrator menu on the control door
- Select Address Locks from the Danger Zone sub-menu and confirm
- The bay LEDs will change and may undergo a firmware update before normal operation resumes
If any issues arise or persist after this process, contact the support team for further advice.
FUYL (MK2)
- Power down the FUYL Locker
- Open the side door with the administrator key
- Ensure the physical connections to each bay are secure
- Manually open each bay using the override levers
- Power on the FUYL Locker (all LEDs should show some activity)
- Access the administrator menu on the control door
- Select Address Locks from the Danger Zone sub-menu and confirm
- Each bay LED will change to yellow (If not, continue this process but note the difference in case the support team is required)
- The screen will display Searching for lock 1
- Close each bay sequentially, waiting for the screen to update before continuing
- After all bays are closed, press "OK" on the PIN keypad
- The bay LEDs will change and may undergo a firmware update before normal operation resumes
If any issues arise or persist after this process, contact the support team for further advice.